soft kernel Search Results


90
Siemens AG siemens convolution kernels
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Siemens Convolution Kernels, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/medium+soft+convolution+kernel+siemens+bv40/pmc04632971-196-18-18
Average 90 stars, based on 1 article reviews
siemens convolution kernels - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens Healthineers b35 kernel
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
B35 Kernel, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+kernel+b30f/10__1097_slash_rti__0b013e31829f6796-106-5-0
Average 90 stars, based on 1 article reviews
b35 kernel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG angio-ct siemens somatom sensation 64 b25f
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Angio Ct Siemens Somatom Sensation 64 B25f, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+kernel+siemens+b25f/pmc05153359-16-13-9
Average 90 stars, based on 1 article reviews
angio-ct siemens somatom sensation 64 b25f - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG bone and soft tissue kernel image reconstructions siemens proprietary kernels b40f
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Bone And Soft Tissue Kernel Image Reconstructions Siemens Proprietary Kernels B40f, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/medium+soft+reconstruction+kernel+b40f/pmc08008399-32-20-30
Average 90 stars, based on 1 article reviews
bone and soft tissue kernel image reconstructions siemens proprietary kernels b40f - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG medium smooth soft tissue convolution kernel siemens b30 kernel
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Medium Smooth Soft Tissue Convolution Kernel Siemens B30 Kernel, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/medium+smooth+soft+tissue+kernel+siemens+b30/pmc04012178-129-22-27
Average 90 stars, based on 1 article reviews
medium smooth soft tissue convolution kernel siemens b30 kernel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens Healthineers iterative reconstruction br40 (mediastinal) kernels
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Iterative Reconstruction Br40 (Mediastinal) Kernels, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+tissue+convolution+kernel+qr40/pmc07494966-146-10-18
Average 90 stars, based on 1 article reviews
iterative reconstruction br40 (mediastinal) kernels - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare spectral reconstruction algorithm with a soft tissue kernel
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Spectral Reconstruction Algorithm With A Soft Tissue Kernel, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/spectral+reconstruction+algorithm+with+a+soft+tissue+kernel/pm37921925-74-10-17
Average 90 stars, based on 1 article reviews
spectral reconstruction algorithm with a soft tissue kernel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG soft tissue kernel b40
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Soft Tissue Kernel B40, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+tissue+reconstruction+kernel+b30/pmc11265490-37-7-13
Average 90 stars, based on 1 article reviews
soft tissue kernel b40 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare soft tissue kernel
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Soft Tissue Kernel, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+tissue+kernel+b/ppr0398624-49-4-8
Average 90 stars, based on 1 article reviews
soft tissue kernel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG medium-soft bone algorithm siemens kernel d30s
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Medium Soft Bone Algorithm Siemens Kernel D30s, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/medium+soft+bone+algorithm+siemens+kernel+d30s/pm37939600-51-6-9
Average 90 stars, based on 1 article reviews
medium-soft bone algorithm siemens kernel d30s - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens Healthineers soft tissue convolution kernel br36
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Soft Tissue Convolution Kernel Br36, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/soft+tissue+convolution+kernel+br36/pm37174949-59-16-50
Average 90 stars, based on 1 article reviews
soft tissue convolution kernel br36 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG reconstruction method fbp algorithm with convolution kernel h31s
Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease
Reconstruction Method Fbp Algorithm With Convolution Kernel H31s, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/soft+kernel/moderately+soft+kernel+siemens+h31s/pmc05127821-79-54-54
Average 90 stars, based on 1 article reviews
reconstruction method fbp algorithm with convolution kernel h31s - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the  convolution  kernel column.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the convolution kernel column.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques: Standard Deviation

Plot of the MTF curves measured on all of the investigated scanners (each manufacturer plotted with a different colour: GE—blue, Siemens—red, and Toshiba—green), along with MTF curves measured using a range of Siemens convolution kernels (dashed black lines), where B10 is the smoothest body kernel and B50 is a very sharp body kernel.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Plot of the MTF curves measured on all of the investigated scanners (each manufacturer plotted with a different colour: GE—blue, Siemens—red, and Toshiba—green), along with MTF curves measured using a range of Siemens convolution kernels (dashed black lines), where B10 is the smoothest body kernel and B50 is a very sharp body kernel.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques:

Statistics of spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2%. Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different  Siemens convolution kernels.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Statistics of spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2%. Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques:

Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease

Journal: Medical image analysis

Article Title: Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study

doi: 10.1016/j.media.2014.07.003

Figure Lengend Snippet: Description of the twenty CT scans that make up the VESSEL12 challenge dataset. Angio-CT: CT with contrast agent, LD: low-dose, HR: high resolution, ILD: (diffuse) interstitial lung disease

Article Snippet: 17 , Angio-CT , Nodules and diffuse abnormalities , Siemens SOMATOM Sensation 64, B25f , 0.59 , 1 , 429 , 100/135.

Techniques: